Home/Products/ABB OVR Series Surge Protective Device
ABB OVR surge protective device
Surge protection · T1 / T2 / T2-T3 · TT / TNC / TNS / IT

ABB OVR Series Surge Protective Device

T1-T2 / T2 / T2-T3 / PV · pluggable · remote signalling

ABB OVR surge protective devices protect electrical systems and equipment against transient surges and impulses caused by the grid or lightning. The range covers power line, data line and photovoltaic applications, with end-of-life indication, safety reserve system, pluggable modules and remote signalling contacts.

T1/T2/T3
Protection classes
TT/TN/IT
Network systems
10/350 μs
T1 impulse waveform
P / TS
Pluggable / signalling

Technical parameters

Data from ABB official OVR product page and FAQ, retrieved 2026-11-21. P/TS and Uc selection rules are quoted from the ABB page.

Protection typesT1 / T2 / T2-T3 power line, data line, PV and self-protected versions
Network systemsTT, TNC, TNS, IT
OVR T1-T2Withstands 10/350 μs impulse current; configuration table lists Iimp 12.5 kA and 25 kA versions
OVR T2 / T2-T3T2 limits transient overvoltages; T2-T3 combination offers low protection level for sensitive equipment
FunctionsEnd-of-life indication, safety reserve system, pluggable design, remote signalling contact
Model suffixP: pluggable; TS: remote signalling contact
Uc selection TT/TNUc > 1.15 × U0 (voltage across SPD)
Uc selection ITUc > 1.732 × U0 (voltage across SPD)
AltitudeSurge discharge capability is independent of altitude; POD backup device usable below 5000 m

Standards & operating conditions

Series branchesOVR Pro, eOVR, OVR QuickSafe (T1-T2 / T2 / T2-T3), OVRF, OVR SC, OVR PV, POD
Selection guidanceABB FAQ references the SPD selection table based on GB 50057-2010 in the OVR catalogue
POD backup protectionPOD is limited to 230/400 V systems and withstands 120 kA lightning current (ABB FAQ)

Key features

Comprehensive protection

Discharges surges caused by direct/indirect lightning and switching, limiting the voltage peak at terminals

OVR + POD coordination

On short circuit POD disconnects quickly; under lightning current it does not trip; on ageing leakage it cuts power to prevent fire

Service-friendly

Pluggable design, end-of-life indication, safety reserve system and remote signalling contact

Extended range

OVR Pro integrated SSD solution, eOVR monitoring and communication, OVR SC for EV charging and OVR PV for photovoltaic systems

Need OVR selection support?

Send us the network system, voltage, protection class and installation point. We will confirm the configuration and offer.

Request a quote