Home/Products/AEG MEAT Low-Voltage Automatic Power Transfer System
AEG MEAT low-voltage automatic power transfer system
Low-voltage ATS · 400-6400 A · E2 / E3 / E3S3 · CCC

AEG MEAT Low-Voltage Automatic Power Transfer System

400-6400 A · 3P / 4P · draw-out ME ACB · Modbus

MEAT is AEG's low-voltage automatic power transfer system built on the ME air circuit breaker and E2 / E3 / E3S3 controllers. It monitors undervoltage, overvoltage and phase loss on the normal supply as well as the standby source, and automatically commands the breakers to complete the transfer. The complete system is CCC certified and is used in power plants, petrochemicals, data centres, hospitals and large commercial buildings.

400-6400 A
Rated current range
3P / 4P
Poles
100 kA
Max Icu (type M)
CCC
Complete system certification

Technical parameters

Data from AEG official Critical Power Transfer Systems handbook, retrieved 2026-11-21.

Product familyAEG MEAT low-voltage automatic power transfer system
System compositionME air circuit breaker combined with E2 / E3 / E3S3 transfer controllers
Transfer schemesE2: two sources; E3: two sources with bus-tie; E3S3: three sources to one downstream load
Rated current400 / 800 / 1000 / 1250 / 1600 / 2000 / 2500 / 3200 / 4000 / 5000 / 6400 A
Poles3P / 4P (selected by system requirement)
Breaking capacity at AC415 VD: Icu=70 kA, Ics=Icw=65 kA; H1: Icu=Ics=80 kA, Icw=65 kA; H2: Icu=Ics=Icw=80 kA; M: Icu=Ics=Icw=100 kA
Breaker protection unitLSI three-stage protection standard for 400-4000 A; other protections optional
Breaker installationDraw-out air circuit breaker as standard
Controller supplyRated voltage AC230 V, 50 Hz; auxiliary supply DC24 V
Sensing inputsS1 / S2 (L-N) for E2 and E3 controllers
Voltage settings (L-N)Undervoltage 150-218 V; overvoltage 242-300 V
CommunicationModbus protocol

Standards & operating conditions

CertificationMEAT complete system certified with CCC
Applicable standard referenceGB/T 14048.11 for automatic transfer switching equipment; ME air breaker standards apply to the built-in breaker
Rated frequency50 Hz
Operating modesAuto-transfer auto-return; auto-transfer non-auto-return; manual and remote operation
Monitoring conditionsUndervoltage, overvoltage, phase loss on the normal supply; voltage status of the standby supply
ApplicationsPower plants, petrochemicals, data centres, public buildings, hospitals, schools and large commercial complexes

Key features

Automatic transfer

Controller detects abnormal voltage or phase loss on any phase and automatically commands the ME breaker to transfer to the standby source

Three transfer schemes

E2 for two sources, E3 for two sources with bus-tie, E3S3 for three sources feeding one downstream load

Generator start and interlock

E2 supports generator start; E3 supports bus-tie; control and protection integrated with mechanical interlocking

Plug-in adapter

Dedicated adapter with quick-connect terminals provides fast connection for E2 and E3 systems

Monitoring and communication

Microprocessor-based controller with preset programmes, Modbus communication, fire interlock and remote operation