AEG MEAT Low-Voltage Automatic Power Transfer System
400-6400 A · 3P / 4P · draw-out ME ACB · Modbus
MEAT is AEG's low-voltage automatic power transfer system built on the ME air circuit breaker and E2 / E3 / E3S3 controllers. It monitors undervoltage, overvoltage and phase loss on the normal supply as well as the standby source, and automatically commands the breakers to complete the transfer. The complete system is CCC certified and is used in power plants, petrochemicals, data centres, hospitals and large commercial buildings.
Technical parameters
Data from AEG official Critical Power Transfer Systems handbook, retrieved 2026-11-21.
| Product family | AEG MEAT low-voltage automatic power transfer system |
| System composition | ME air circuit breaker combined with E2 / E3 / E3S3 transfer controllers |
| Transfer schemes | E2: two sources; E3: two sources with bus-tie; E3S3: three sources to one downstream load |
| Rated current | 400 / 800 / 1000 / 1250 / 1600 / 2000 / 2500 / 3200 / 4000 / 5000 / 6400 A |
| Poles | 3P / 4P (selected by system requirement) |
| Breaking capacity at AC415 V | D: Icu=70 kA, Ics=Icw=65 kA; H1: Icu=Ics=80 kA, Icw=65 kA; H2: Icu=Ics=Icw=80 kA; M: Icu=Ics=Icw=100 kA |
| Breaker protection unit | LSI three-stage protection standard for 400-4000 A; other protections optional |
| Breaker installation | Draw-out air circuit breaker as standard |
| Controller supply | Rated voltage AC230 V, 50 Hz; auxiliary supply DC24 V |
| Sensing inputs | S1 / S2 (L-N) for E2 and E3 controllers |
| Voltage settings (L-N) | Undervoltage 150-218 V; overvoltage 242-300 V |
| Communication | Modbus protocol |
Standards & operating conditions
| Certification | MEAT complete system certified with CCC |
| Applicable standard reference | GB/T 14048.11 for automatic transfer switching equipment; ME air breaker standards apply to the built-in breaker |
| Rated frequency | 50 Hz |
| Operating modes | Auto-transfer auto-return; auto-transfer non-auto-return; manual and remote operation |
| Monitoring conditions | Undervoltage, overvoltage, phase loss on the normal supply; voltage status of the standby supply |
| Applications | Power plants, petrochemicals, data centres, public buildings, hospitals, schools and large commercial complexes |
Key features
Automatic transfer
Controller detects abnormal voltage or phase loss on any phase and automatically commands the ME breaker to transfer to the standby source
Three transfer schemes
E2 for two sources, E3 for two sources with bus-tie, E3S3 for three sources feeding one downstream load
Generator start and interlock
E2 supports generator start; E3 supports bus-tie; control and protection integrated with mechanical interlocking
Plug-in adapter
Dedicated adapter with quick-connect terminals provides fast connection for E2 and E3 systems
Monitoring and communication
Microprocessor-based controller with preset programmes, Modbus communication, fire interlock and remote operation