AEG SecoVac VB2 Plus G generator circuit breaker
Generator circuit breaker · 15 kV · 2500-5000 A · IEC/IEEE dual standard

AEG SecoVac VB2 Plus G Generator Circuit Breaker

15 kV · 2500-5000 A · 31.5-50 kA · IEC/IEEE 62271-37-013

AEG/GEIS SecoVac VB2 Plus G is a generator circuit breaker installed between the generator and step-up transformer. It is designed and tested to IEC/IEEE 62271-37-013 for high continuous current, high DC components, delayed current zero and severe transient recovery voltages.

15 kV
Rated voltage
2500-5000 A
Rated current
50 kA
Max system-source breaking
130%
Generator-source DC component

Technical parameters

Data from SecoVac medium-voltage breaker catalog ACNCMVAA24V1 and SecoVac VB2 Plus IEEE brochure GENCMVAF26V1. * 4000/5000 A versions require forced air cooling; confirm exact current and breaking-current combinations before ordering.

SeriesAEG / GEIS SecoVac VB2 Plus G
Rated voltage15 kV
Rated frequency50 / 60 Hz
Rated current2500 / 3150 / 4000* / 5000* A
System-source fault breaking current (Isc)31.5 / 40 / 50 kA
Generator-source fault breaking current (Iscg)15.8 / 25 / 25 kA
Out-of-step making / breaking current15.8 / 20 / 25 kA
Short-time withstand current (3 s)31.5 / 40 / 50 kA
Peak withstand / making current86.3 / 110 / 137 kA
DC component75% system-source; 130% generator-source
TRV peak / rate of rise27 kV, 3.5 kV/us (system and generator source); 39 kV, 3.3 kV/us (out-of-step)
Rated operating sequenceCO-30min-CO
Mechanical life10,000 operations
Opening / closing time20-50 ms / 30-70 ms
Main-circuit resistance<= 35 micro-ohm
Closing / opening and motor voltageAC 110/220 V, DC 110/220 V; charging time <= 10 s
ConstructionWithdrawable (W) or fixed (F); 275 mm pole centres; spring mechanism

Standards & operating conditions

The VB2 Plus G generator circuit breaker was type-tested at KEMA and meets the IEC/IEEE dual-standard requirements for generator circuit breakers.

Generator circuit-breaker standardIEC/IEEE 62271-37-013, tested at KEMA
IEC / GB / DL standardsIEC 62271-100:2012; IEC 60694:2002; GB/T 1984-2014; DL/T 403-2000; DIN VDE 0671
IEEE application referenceIEEE C37.04, C37.06, C37.09, C37.20.2 for the 15 kV VB2 Plus family
Ambient temperatureMax +40 °C; min -15 °C (standard order); max daily average +35 °C
Relative humidity at 25 °CDaily average <= 95%; monthly average <= 90%
AltitudeStandard version up to 1000 m; high-altitude version on request
Site conditionsIndoor; no dripping water, fire/explosion hazard, corrosive gas, severe pollution or violent vibration

IEEE supplement: SecoVac VB2 Plus IEEE brochure (PDF)

Key features

Built for generator circuits

Installed between the generator and step-up transformer, with higher continuous current, breaking current and DC-component capability than general distribution breakers.

Severe fault conditions

Designed for high system-source DC components (75%), delayed current zero under generator-source faults (up to 130% asymmetry) and high TRV/RRRV stresses.

Out-of-step switching

Capable of making and breaking under out-of-phase conditions, with recovery voltage across the open contacts reaching twice the rated phase-to-earth voltage at 90 degrees.

Typical applications

Power plants, mining, standby/backup generation, semiconductor manufacturing and data-centre generator sets, including unit-connected generator-transformer arrangements.