AEG SecoVac VB2 Plus medium voltage vacuum circuit breaker
SecoVac VCB · 12/24 kV · 630-5000 A · up to 50 kA

AEG SecoVac VB2 Plus Vacuum Circuit Breaker

12 / 24 kV · 630-5000 A · 25-50 kA · 30,000 operations

AEG/GEIS SecoVac VB2 Plus is an indoor three-phase AC vacuum circuit breaker for 12 kV and 24 kV distribution systems. It is available in withdrawable or fixed constructions for frequent operation in industrial, power plant and substation applications.

12 / 24 kV
Rated voltage
630-5000 A
Rated current
50 kA
Max breaking current
30,000
Mechanical operations

Technical parameters

Data from SecoVac medium-voltage breaker catalog ACNCMVAA24V1 and VB2 Plus IEEE brochure GENCMVAF26V1. * 4000/5000 A versions use forced air cooling; exact current/breaking-current combinations are confirmed in the order form.

SeriesAEG / GEIS SecoVac VB2 Plus
Rated voltage12 / 24 kV
Rated frequency50 Hz
Rated current at 12 kV630 / 1250 / 1600 / 2000 / 2500 / 3150 / 4000* / 5000* A
Rated current at 24 kV630 / 1250 / 1600 / 2000 / 2500 / 3150* A
Power-frequency withstand voltage (1 min)42 kV (12 kV) / 65 kV (24 kV)
Lightning impulse withstand voltage75 kV (12 kV) / 125 kV (24 kV)
Rated short-circuit breaking current12 kV: 25 / 31.5 / 40 / 50 kA; 24 kV: 25 / 31.5 kA
Short-time withstand current (4 s)12 kV: 25 / 31.5 / 40 / 50 kA; 24 kV: 25 / 31.5 kA
Peak withstand / making current12 kV: 63 / 80 / 125 / 135 kA; 24 kV: 63 / 80 kA
Rated operating sequenceO-0.3s-CO-180s-CO
Single / back-to-back capacitor bank breaking current630 / 400 A
Mechanical life30,000 operations
Opening / closing time20-50 ms / 30-70 ms
Closing / opening and motor voltageAC 110/220 V, DC 110/220 V; charging time <= 10 s
ConstructionWithdrawable (W) or fixed (F); spring operating mechanism

Standards & operating conditions

The SecoVac series is type-tested for temperature rise, dielectric withstand, short-time and peak withstand current, mechanical life and short-circuit switching capability.

GB / DL standardsGB/T 1984-2014; DL/T 403-2000
IEC / DIN standardsIEC 62271-100:2012; IEC 60694:2002; DIN VDE 0671
IEEE version (15 kV class)IEEE C37.04, C37.06, C37.09, C37.20.2
Ambient temperatureMax +40 °C; min -15 °C (standard order); max daily average +35 °C
Relative humidity at 25 °CDaily average <= 95%; monthly average <= 90%
AltitudeStandard version up to 1000 m; high-altitude version on request
Seismic intensityNot exceeding 8 degrees
Site conditionsIndoor; no dripping water, fire/explosion hazard, corrosive gas, severe pollution or violent vibration

IEEE supplement: SecoVac VB2 Plus IEEE brochure (PDF)

Key features

Vacuum interrupter

One-shot sealing process, high vacuum up to 10^-5 Pa and axial magnetic field interruption for strong arc extinction and long contact life.

Solid-encapsulated pole

The high-voltage circuit is fully encapsulated in solid insulation, reducing environmental influence and providing maintenance-free pollution and salt-spray resistance.

Modular spring mechanism

Modular design with integrated energy-storage shaft, motor/manual clutch, holding latch and cam output for stable operation and easy accessory fitting.

Smart-ready options

Optional temperature monitoring, mechanical-characteristic and secondary-component monitoring, motor-driven trolley control and digital analysis for predictive maintenance.

Need a SecoVac VB2 Plus quote or selection support?

Send us the voltage, rated current, breaking current, installation type and control voltage. We will confirm the configuration and offer.

Request a quote