AEG ALPS US3.0 SF6 gas-insulated ring main unit
SF6 RMU · 12 / 24 kV · IP67 gas tank · maintenance-free

AEG ALPS US3.0 SF6 Gas-Insulated Ring Main Unit

12/24 kV · 630 A load switch · 25 kA breaker · IP67 / IP4X

ALPS US3.0 is an SF6 gas-insulated indoor ring main unit from AEG / GEIS for 12-24 kV distribution systems. All HV live parts are sealed in the SF6 gas tank, making it maintenance-free and unaffected by the environment. Its compact modular design allows free extension on both sides and configuration with load switches, fuse-switch combinations and vacuum breakers.

12/24 kV
Rated voltage
630 A
Load switch current
25 kA
Breaker breaking
IP67
Gas tank protection

Technical parameters

Data from AEG official US3.0 gas-insulated RMU brochure, retrieved 2026-11-21.

Product familyALPS US3.0 SF6 gas-insulated indoor ring main unit
Rated voltage12 kV / 24 kV
Rated frequency50 Hz
Power frequency withstand42 / 65 kV phase-to-earth; 48 / 79 kV across isolation distance (1 min)
Lightning impulse withstand95 / 125 kV phase-to-earth; 110 / 145 kV across isolation distance
Degree of protectionGas tank IP67 (optional IP68); switchgear housing IP4X (optional IP42)
SF6 pressure0.03 / 0.045 MPa rated at 20 °C gauge; minimum 0.02 / 0.025 MPa
Sealing performanceAnnual leakage rate no more than 0.01% / year
Load switch unit630 A; short-time withstand 20 kA / 4 s; mechanical endurance 6000 operations (12 kV)
Fuse-switch unitCurrent depends on fuse; rated breaking current 31.5 kA; mechanical endurance 5000 operations
Vacuum breaker unitRated short-circuit breaking current 25 kA; mechanical endurance 10000 operations

Standards & operating conditions

StandardsGB/T 11022, GB 3906, GB 3804, GB/T 16926, GB 1985, GB 1984; IEC 60694, IEC 62271-200/100/102/105
Ambient temperature-40 °C to +55 °C
HumidityMax daily average relative humidity 95%; max monthly average 90%
AltitudeNot exceeding 2000 m (another brochure: 3000 m)
SeismicSeismic intensity not exceeding 8 degrees
Special conditionsNon-standard conditions to be agreed with the manufacturer per IEC 60694

Key features

SF6 full insulation

All HV live parts sealed in the SF6 gas tank, unaffected by environment and maintenance-free

Laser-welded tank

3 mm stainless steel gas tank with automatic laser welding for 40 years safe service

Flexible extension

Busbar can extend freely on both sides via connectors; compact module structure

Safety design

Rupture disc set at 2.5 times standard atmospheric pressure; flood-resistant design

Smart grid ready

Optional telemetry, telecontrol and relay protection devices for monitoring and smart grid access

Need US3.0 configuration support?

Send us the voltage, unit combination (C / F / CB) and quantity. We will confirm the configuration and offer.