Technical parameters
Data from Schneider EasyPact CVS catalog 2025. Icu/Ics vary by frame and breaking type; confirm the exact configuration before ordering.
| Frames | CVS63 / 100 / 125 / 160 / 250 / 400 / 630 |
| Poles | 3 / 4 |
| Rated current In @40 °C | 16 - 630 A (by frame) |
| Rated insulation voltage Ui | 690 V |
| Rated impulse withstand voltage Uimp | 6 / 8 kV (by frame) |
| Rated operational voltage Ue | AC 50/60 Hz, 440/500 V |
| Ultimate breaking capacity Icu @220/230 V | Up to 100 kA rms (B/F/N/HM types) |
| Ultimate breaking capacity Icu @380/400 V | Up to 70 kA rms |
| Service breaking capacity Ics @220/230 V | Up to 75 kA rms |
| Utilisation category | A |
| Isolation function | Yes, compliant with IEC 60947-2 |
| Mechanical life (C-O cycles) | 13,000 - 20,000 |
| Electrical life @415 V | Up to 8,000 (In/2), 4,000 (In) |
| Trip unit | Thermal-magnetic; VigiPact residual-current relay available |
| Mounting / connection | Fixed front, plug-in and drawout (CVS100) |
Standards and environment
| Standards | IEC 60947-1 / IEC 60947-2 / GB 14048.1 / GB 14048.2 |
| Pollution degree | III (industrial, per IEC 60947-1 / 60664-1) |
| Operating temperature | -25 ~ +70 °C (derating above 40 °C; motor protection above 65 °C) |
| Storage temperature | -50 ~ +85 °C |
| Degree of protection | Bare breaker: IP40/IK07 (toggle), IP54/IK08 (extended rotary handle) |
| Environment | RoHS compliant; production sites ISO 14001 |
Key features
Reliable isolation
All CVS breakers comply with IEC 60947-2 isolation: OFF isolation position, padlock only with contacts open, reliable position indication even with rotary/motor operators.
Class II insulation
All breakers are Class II insulated and can be installed in Class II switchgear without reducing insulation level.
Residual current protection
VigiPact residual-current relays can be combined with CVS breakers for earth leakage protection.
Complete accessories
Auxiliary contacts, shunt trip, undervoltage release, rotary handles, phase barriers and plug-in/drawout bases.
Need a CVS quote or selection support?
Send us the frame current, poles, breaking capacity and mounting type. We will confirm the exact configuration and offer.