EasyPact EZD moulded case circuit breaker
Moulded case circuit breaker · 100-630 A · 3P/4P

EasyPact EZD MCCB

100-630 A · Ui 690 V · Icu up to 100 kA · thermal-magnetic

Schneider EasyPact EZD moulded case circuit breakers, 100-630 A, 3/4 poles, designed for secondary distribution, civil buildings and M&E applications. Complete functions, flexible installation, easy maintenance and excellent value.

100-630 A
Rated current
690 V
Insulation voltage
100 kA
Max breaking capacity
3P/4P
Poles

Technical parameters

Data from Schneider EasyPact EZD catalog 2025. Icu/Ics vary by frame and type; confirm the exact configuration before ordering.

Frame / rated current In (40 °C)EZD100/125/160/250/400/630: 100 / 100 / 125 / 160 / 250 / 400 / 630 A
Poles3 / 4
Rated insulation voltage Ui690 V
Rated impulse withstand voltage Uimp6 kV
Rated operational voltage UeAC 50/60 Hz, 550 V (100-250), 440 V (400-630)
Ultimate short-circuit breaking capacity Icu @380/400 VUp to 50 kA rms (by type B/F/N/E/M/S)
Ultimate breaking capacity Icu @220/230 VUp to 100 kA rms
Service short-circuit breaking capacity IcsUp to 70 kA @220/230 V; up to 50 kA @380/400 V
Utilisation categoryA
Isolation functionYes, compliant with IEC 60947-2
Mechanical life (C-O cycles)8,500 - 10,000
Electrical life @400 V In4,000 - 5,000
Trip unitThermal-magnetic (EZD630: electronic)
Mounting / connectionFixed, front connection; plug-in available (160-630)

Standards and environment

StandardsIEC 60947-2 / EN 60947-2 / GB 14048.2
Operating temperature-25 ~ +70 °C (100% performance at 50 °C for 100-250 A, 40 °C for 400-630 A)
Storage temperature-35 ~ +85 °C
Damp heatIEC 60068-2-30: 95% RH at 45 °C; salt mist IEC 60068-2-11

Key features

Easy to use

Complete function set, flexible installation and simple maintenance; ideal for secondary distribution, civil building and M&E markets.

Reliable isolation

All EZD breakers are suitable for isolation per IEC 60947-2: contact isolation at OFF, padlock only when all contacts open, reliable position indication.

Wide accessory range

Auxiliary contacts AX/AL, shunt trip SHT, undervoltage release UVR, PM2000 metering with Modbus communication, rotary handles.

Residual current version

VigiEZD residual-current breakers available with adjustable sensitivity 0.03-1 A and adjustable time delay.