GEIS MAST Metal-Clad Switchgear
5-15 kV · 1200/2000 A · 31.5/40 kA · two-high breaker
GEIS MAST is a metal-clad switchgear fully tested to IEEE standards for 5-15 kV, 50/60 Hz, 1200-2000 A and up to 40 kA short-circuit rating. It uses SecoVac embedded-pole vacuum circuit breakers in a two-high, indoor NEMA 1 enclosure.
Technical parameters
Data from GEIS MAST Metal-Clad Switchgear Catalogue (IEEE version). Values vary by configuration; confirm the exact breaker and switchgear rating before ordering.
| Series | GEIS MAST Metal-Clad Switchgear |
| Rated maximum voltage | 15 kV (5-15 kV applications) |
| Rated maximum continuous current | 1200 / 2000 A (switchgear); SecoVac VB2 Plus-15 breaker up to 3000 A |
| Rated frequency | 50 / 60 Hz |
| Power-frequency withstand voltage (1 min) | Phase-to-phase / to earth 36 kV; across isolating distance 36 kV (breaker 36/40 kV) |
| Lightning impulse withstand voltage | Phase-to-phase / to earth 95 kV; across isolating distance 95 kV (breaker 95/105 kV) |
| Rated short-time withstand current | 31.5 / 40 kA (2 s) |
| Rated peak withstand current | 82 / 104 kA |
| Rated short-circuit breaking current | 31.5 / 40 kA |
| Enclosure | Indoor NEMA 1; metal-clad, fully compartmentalized with grounded metal barriers |
| Construction | Two-high breaker stacking; withdrawable breakers, VT/CPT and fuse trucks |
| External dimensions (W x D x H) | 914 x 2387 x 2413 mm (36 x 94 x 95 inch) |
| Circuit breaker | SecoVac VB2 Plus-15 embedded-pole VCB, GAL spring mechanism, 60,000 mechanical operations tested (design life up to 90,000) |
Standards & operating conditions
| IEEE standards | IEEE C37.20.2, C37.04, C37.06, C37.09, C37.010, C37.012, C37.11, C37.100.1 |
| Ground and test device | IEEE Std C37.20.6 (4.76-15 kV grounding and testing devices) |
| Operating ambient temperature | Maximum +40 °C; minimum -30 °C; daily average <= 35 °C |
| Storage ambient temperature | Maximum +40 °C; minimum -40 °C; dry place away from direct sunlight and rain |
| Altitude | Maximum 2000 m (6600 ft) |
| Relative humidity | 24-hour average <= 95%; 1-month average <= 90% |
Key features
Design for safety
Fully compartmentalized construction with grounded metal barriers between breaker, bus, cable and control compartments; automatic grounded shutters and comprehensive interlocking.
Standard interlocking
Breaker can only move between test and connect positions when open; secondary plug can only be removed at test position; breaker cannot be closed between positions; shutters close automatically on racking out.
Two-high configuration
Two-high breaker stacking gives flexible configuration, reduced floor space and easy expansion; Main-Tie-Main combinations available.
Drawout design
Drawout circuit breakers, VT/CPT and fuse trucks for easy maintenance; lift truck and optional ground-and-test device for safe handling and testing.
Applications
Utilities and power plants, network substations, generator switchgear, oil and gas, mining, pulp and paper, data centres, hospitals, airports and railways.