Schneider I-LINE W Busway System
400-5000 A · 1000 V · IP54/65/66 · Icw up to 100 kA
Schneider Electric I-LINE W is a copper busway system for medium and high current distribution from 400 A to 5000 A. It uses a sandwich conductor arrangement, silver-plated copper conductors and a fully enclosed housing, with CCC certification and optional smart temperature monitoring.
Technical parameters
Data from Schneider I-LINE W catalog SCDOC1897 (2024). Icw and Ipk values depend on the current rating; confirm the exact configuration before ordering.
| Series | Schneider Electric I-LINE W |
| Rated current | 400 / 630 / 800 / 1000 / 1250 / 1600 / 2000 / 2500 / 3200 / 4000 / 5000 A |
| Rated operational voltage | 1000 V |
| Rated insulation voltage | 1000 V |
| Frequency | 50 Hz |
| Enclosure protection degree | IP54 / IP65 / IP66 |
| Rated short-time withstand current Icw (3C report) | 20 kA (400 A) / 30 kA (630-800 A) / 50 kA (1000-1250 A) / 80 kA (1600-3200 A) / 100 kA (4000-5000 A) |
| Rated peak short-circuit current Ipk (3C report) | 40 kA (400 A) / 63 kA (630-800 A) / 105 kA (1000-1250 A) / 176 kA (1600-3200 A) / 220 kA (4000-5000 A) |
| Conductor | High-purity electrolytic copper, silver-plated contact surfaces |
| Conductor resistance R20 | 0.205 mΩ/m (400 A) to 0.012 mΩ/m (5000 A), by rating |
| Voltage drop (40 °C, full load, cosφ=1) | 0.176 V/m (400 A) to 0.132 V/m (5000 A) |
| Temperature derating factor | 1.0 at 40 °C; 0.93 at 45 °C; 0.87 at 50 °C; 0.82 at 55 °C; 0.78 at 60 °C; 0.74 at 65 °C; 0.71 at 70 °C |
Standards & certification
| Product certification | CCC certification for the full I-LINE W range |
| Standards | GB/T 7251.1 and GB/T 7251.6 |
| Insulation material | Polyester film, class B 130 °C; >=5000 h test per GB/T 11026.1; halogen-free, UL94 flame retardant |
| Plug-in unit | 16-800 A; built-in Schneider breaker, breaking capacity up to 70 kA, Ics=100% Icu, mechanical life 50,000 operations, IP54 |
Key features
Sandwich construction
Conductors are closely arranged for overall heat dissipation, giving lower temperature rise and a compact footprint.
Fully enclosed housing
Improves protection, reduces dust accumulation, eliminates direct contact with live parts and offers good corrosion resistance.
Fire safety
Internal smoke barriers prevent smoke spreading through the busway; all parts are halogen-free, with no smoke or toxic gas in fire.
Smart temperature monitoring
Zigbee-based monitoring can track more than 1,000 temperature points on one busway run and integrate with EcoStructure.
Applications
Transformer-to-switchgear connections, horizontal workshop distribution and vertical riser supply in high-rise buildings.
Need an I-LINE W busway quote or selection support?
Send us the current rating, voltage, protection degree, route layout and tap-off requirements. We will confirm the configuration and offer.