Siemens SENTRON 3WL Withdrawable Air Circuit Breaker
800-6300 A · Ue 1000 V · Icu up to 100 kA · 4 switching positions
SENTRON 3WL withdrawable air circuit breakers use a guide frame with connected, test, disconnected and withdrawn positions, allowing safe maintenance without removing main busbars. They cover 800 A to 6300 A with electronic trip units and communication options.
Technical parameters
Data from the official Siemens SENTRON 3WL Chinese catalog (2015) and LV10 3WL11-13 catalog (2019). Values vary by model and configuration; confirm the exact order code before quotation.
| Product family | SENTRON 3WL air circuit breaker, withdrawable version (3WL11 / 3WL12 / 3WL13) |
| Mounting version | Withdrawable, with guide frame (3-pole / 4-pole) |
| Rated current In | 800 - 6300 A (AC); up to 4000 A (DC) |
| Rated operational voltage Ue | AC 690 / 1000 V; DC 600 / 1000 V |
| Rated insulation voltage Ui | 1000 V |
| Rated impulse withstand voltage Uimp | 12 kV (main circuit); 2.5 kV (control circuit) |
| Rated ultimate short-circuit breaking capacity Icu | Up to 100 kA at 415 V (version dependent) |
| Rated short-time withstand current Icw | Up to 100 kA / 0.5 s, 85 kA / 1 s (version dependent) |
| Switching positions | Connected, test, disconnected and withdrawn positions |
| Trip unit | Electronic trip units ETU45B / ETU76B (with communication and metering) |
| Communication | COM15 PROFIBUS, COM16 MODBUS, COM35 PROFINET IO / Modbus TCP |
| Degree of protection | IP20 (circuit breaker); IP41 with door sealing frame |
| Mechanical life | Up to 25000 operating cycles (with maintenance) |
Standards & operating conditions
| Standards | IEC/EN 60947-2 |
| Isolation function | Yes, compliant with IEC 60947-2 |
| Ambient temperature | Operation -40 ... +70 °C; storage -40 ... +80 °C |
| Installation altitude | Up to 2000 m without derating |
| Safety | Safety shutters, grounding contacts and position signal contacts on guide frame |
Key features
Withdrawable design
Guide frame allows connected, test, disconnected and withdrawn positions for safe maintenance without disconnecting main busbars.
Wide current range
3WL withdrawable versions cover 800 A to 6300 A AC with breaking capacities up to 100 kA.
Communication and metering
Optional COM15/COM16/COM35 modules and ETU76B trip unit provide communication, metering and energy management.
Long service life
Mechanical life up to 25000 operating cycles with maintenance; modular accessories retrofit without replacing the breaker.