Home/Products/Siemens SENTRON 5SD7 Surge Protective Device
Siemens SENTRON 5SD7 surge protective device
Type 1 / 2 / 3 · up to 100 kA · EN 61643-11 · plug-in

Siemens SENTRON 5SD7 Surge Protective Device

Type 1 / 1+2 / 2 / 3 / PV · 255 V AC · 25-100 kA · TN-C / TN-S / TT

SENTRON 5SD7 is Siemens' surge protective device family for low-voltage distribution, covering Type 1 lightning arresters, Type 1+2 and 1/2 combination arresters, Type 2 and Type 3 SPDs, PV surge arresters and devices for measuring and control circuits. A coordinated three-level protection concept covers everything from the building entry to sensitive terminal equipment.

100 kA
Max lightning current
20 kA
Type 2 nominal discharge
1.0 kV
Type 3 protection level
EN 61643-11
Standard

Technical parameters

Data from Siemens China official SENTRON overvoltage protection page and official configuration manual, retrieved 2026-11-21.

Product familySENTRON 5SD7 surge protective devices (SPD)
Protection typesType 1, Type 1+2, Type 1/2, Type 2, Type 3, PV type 2, and measuring/control technology
Type 1 lightning arresterPlug-in modules for TN-C, TN-S, TT; rated voltage 350 V AC; lightning current 25-100 kA; remote signalling contact
Type 1+2 combinationRated voltage 255 V AC (brochure: 350 V AC); lightning current 25-100 kA; remote contacts
Type 2 SPDRated voltage 255 V AC; rated discharge current 20 kA; discharge surge current 40 kA
Type 3 SPDLow protection level up to 1.0 kV; discharge current up to 3 kA; single-phase 24/120/230 V AC, three-phase 230/400 V AC
PV surge arresterType 2 for system voltages up to 1500 V DC; protects inverters and PV strings
Network systemsTN-C, TN-S, TT (plug-in protective modules)

Standards & operating conditions

StandardsEN 61643-11 (power); EN 61643-21 (measuring and control technology)
Protection conceptCoordinated three-level protection concept; IEC 61312-1 defines additional surge protection measures
InstallationType 1 in main distribution boards; Type 2 in sub-distribution boards; Type 3 close to terminal equipment
Status & maintenanceMechanical fault indication, plug-in modules, visual indicators and remote contacts
Busbar versionType 1+2+3 version for 44 mm busbar

Key features

Three-level protection

Coordinated protection from the building entry to sensitive terminal equipment, tailored to local conditions and loads

Ensure compliance

Coordinated three-level concept based on international standards with effective energy discharge

Increase availability

Compact design, pluggable modules, visual indicators and remote contacts enable fast installation and transparent monitoring

Plug-in protective modules

Protective modules available as connectors; remote signalling contact indicates device failure

Photovoltaic protection

Dedicated type 2 SPD for PV systems up to 1500 V DC with high discharge capacity

Need 5SD7 surge protection?

Send us the protection type, network system and installation location. We will confirm the configuration and offer.

Request a quote